Vlf Cable Testing Voltage
Vlf testing of shielded power cables by paul brooker consultant to techrentals division of tr corporation.
Vlf cable testing voltage. Trusted for the most technically advanced portable and user friendly high voltage equipment on the market. Unlike with dc voltage testing very low frequency is not destructive to good insulation and does not lead to premature failures. A vlf test. Vlf testing can be classified as a withstand or diagnostic test meaning it may be performed as a proof test for acceptance or as a maintenance test for assessing the condition of cable.
A very low frequency vlf withstand test is an ac withstand test usually carried out at a frequency between 0 1 hz and 0 01 hz. In the first step a go no go statement is sufficient. This combination of size and power makes very low frequency cable testing perfect for testing longer sections of cable and apparatus. The test is conducted on entire drum of cable rather than a test sample length.
Vlf testing is a withstand test usually carried out at a frequency of between 0 1 hz and 0 01 hz rather than 50 60 hz. Designs and manufactures industry leading high voltage test equipment for proof testing diagnostic testing high voltage breakdown testing and preventative maintenance testing. Very low frequency vlf withstand testing is the application of an ac sinusoidal waveform generally at 0 01 0 1 hz to assess the quality of electrical insulation in high capacitive loads such as cables. During the test cables are subjected to a test voltage significantly higher than what they experience during normal operating conditions.
Vlf cable testing makes use of ac voltages in a frequency range of 0 01. The most commonly used commercially available vlf ac voltage test frequency is 0 1 hz. Vlf systems are advantageous in that they can be manufactured to be small and lightweight. Very low frequency testing for medium voltage and high voltage cables is a method for verifying the integrity of the cable insulation.
This kind of test is suited for testing high capacitance loads such. This article reviews the application of very low frequency vlf ac high voltage test sets for commissioning and maintenance of shielded medium voltage cables. The implication of dc hipot testing. Vlf cable testing is the cutting edge technology for proof testing of fully operating medium voltage cables and the detection of faulty ones.
However there is a risk that the cable may be understated due to a combination of lower test voltage and allowed uncertainty of the measuring circuit. Ac is the standard used to transmit power worldwide usually at a frequency of 50 or 60 hertz. Vlf cable testing very low frequency is a technique for testing of medium and high voltage mv and hv cables. Making them useful especially for field testing where transport and space can be issues.
The device under test must withstand a vlf very low frequency ac voltage for a preset testing time without flashover.