Voltage Limiting Device Siemens
Voltage limiting device based on a mechanical breaker and additional solid state electronic switching elements e g.
Voltage limiting device siemens. They do not require a power supply and can be used along the railway line. Voltage limiting devices estra vguard. Our high voltage disconnectors and earthing switches combine state of the art technology with the highest quality standards for a voltage range from 36 kv to 800 kv. Voltage limiting device tzd 1nr becomes conductive when the voltage at its terminals approaches triggering voltage.
It is important to ensure high system availability and optimize energy consumption while protecting people and plants. It happens when the earth fault occurs. Learn more about the range and technology of our high voltage disconnectors and earthing switches. Device voltage limiting device for dc traction power supply in dc traction systems impermissible touch voltages may occur between return circuit and structure earth due to operational currents short circuit currents and the interaction of ac and dc traction power supply systems.
In dc traction systems impermissible contact voltage can occur between the return circuit and the structure ground due to operational currents and short circuit currents. Voltage limiting devices bvl 50 120 r01 bvl 100 120 r01 voltage limiting device vld of class 2 2 and a surge protective device spd of type 1 and 2 bvl 50 bvl 100 provides the temporary connection be tween the return circuit and the earth of the railway electric traction system during the permissible value of touch voltage is exceeded. Beginning with the end device and all the way upstream to the entry of the power lines into the building all power lines as well as the communication lines should be provided with overvoltage protection. The persistence of these voltages must be prevented by a suitable voltage limiting device in accordance with iec 62128 1 en 50122 1.
Transient surges caused by lightning and switching operations in the system are limited by the mo arrester. Tzd 1nr conducts current till the opening of high speed circuit breaker in substation and then it returns to non conductive state recovers. Thyristors devices of classes 1 and 2 are passive i e. It s best when all electrically live cable routes in the building exposed to hazards are safeguarded by suitable protection devices according to a systematic graded protection concept.
Sécheron s vguard voltage limiting device is built on proven technologies and meets the electrical safety and internal arc testing requirements in the en 50122 1 and en 50526 2 standards. If surges occur for a longer period of time milliseconds to hours due to.